Description
DESCRIPTION
ECP 581 is a single component, black coloured acrylic paint in aerosol form to provide a convenient method of application for prototype, design and touch-up work; it is specially formulated to minimise settling and to provide a homogeneous finish.
Applied coating is compliant with BS IEC 61340-5-3:2010 Basic Specification for the Handling of Electro Static Devices and is fully ATEX compliant.
PHYSICAL PROPERTIES
Surface resistivity at 50 micron <106 ohm/square or less
(2 thou) ASTM D257
Colour Black
Coverage Approx 6 square feet
Recommended dry film thickness 50 micron (2 thou)
Drying time: Touch 15 minutes
Full 12 hours
Contents 400 ml
Shelf Life 12 months
METHOD OF USE
Surface preparation: All contaminants including mould release, grease and dirt must be removed. Mask areas that do not require spraying.
Mixing: Shake vigorously for a minimum of 2 minutes to evenly distribute contents.
Spray a small area to check compatibility with substrate.
Application: Operate in an upright position, spraying in light, even strokes from side to side to avoid flooding. Shake briefly at intervals during spraying. On completion, invert the
aerosol and spray to clear valve and nozzle. It is advised to clear any excess material
from the nozzle at frequent intervals to prevent blockage. If the nozzle blocks, use a pin
to clear the opening, or remove the nozzle and flush with Toluene, Xylene or MEK.
It is advised to coat several thinner coats than try to coat heavily in one pass.
PRECAUTIONS:
Pressurised container. Protect from sunlight and do not expose to temperature exceeding 50oC. Do not pierce or burn, even after use. Do not spray on an open flame or any incandescent material. Keep away from sources of ignition – No smoking.
Use under well ventilated conditions: Contains inorganic fillersl / xylene mix / toluene. Harmful by inhalation. Do not breathe vapour. In case of insufficient ventilation – wear suitable respiratory equipment, which must be used in accordance with the manufacturer’s instructions. For excessive vapour inhalation, remove to fresh air and summon medical attention.
Avoid contact with skin and eyes): In case of skin contact, wash with soap and water, dry and apply work cream. Eye Contact – flush with water for at least 15 minutes and seek medical attention. If accidentally swallowed, summon medical attention.