Description
FLOORSHIELD-HP-ESP
DESCRIPTION
FloorShield-HP-ESP a high performance conductive industrial flooring surface hardener and protective clear coat. This floor treatment is a microfilm forming hybrid inorganic/organic nano lithium with CNT + Graphene coating that hardens and seals concrete floors, producing a very hard, dust repellent, chemical resistant and watertight surface. With surface resistance <109Ω it is fully compliant the requirements for ATEX and BS EN 61340-5-1.
For high demand, commercial and industrial settings, FloorShield-HP-ESP is the optimum coating system designed for harsh and high abuse conditions. Whether your surface must tolerate significant foot traffic, large equipment, abrasion, or chemicals our advanced, versatile, low VOC treatment offers high durability and bond strength with the ability to withstand UV, abrasion, chemical spills and heavy traffic
FloorShield-HP-ESP provides rapid curing, attractive clear glossy finish and easy application for facilities that require maximum protection and little or no downtime. This unique treatment is extremely low in VOC’s (<50g/lt) and environmentally with low odour.
FloorShield-HP-ESP is perfect for protecting light to heavy manufacturing floors, driveways, garage floors, food operations and warehouses. FloorShield-HP-ESP leaves concrete hard, stain resistant, easy to maintain and light reflective (on smooth finishes). FloorShield-HP-ESP does not significantly decrease the friction coefficient of surfaces
.
BENEFITS:
- Combines the durable protection of a penetrating densifier with the attractive finish of a high-performance glossy coating.
- Creates a stronger more impenetrable and a better looking finish that is dust proof, stain resistant (oils and many acids) and prevents against deterioration.
- Produces an attractive easy to maintain yet tough coating for high abuse areas, such as chemical exposure, impact or abrasion.
- Tenaciously bonds and reacts with concrete forming a durable insoluble bond with the concrete.
- Forms a protective “micro surface layer” that is breathable, dense and abrasion resistant that will not peel or flake.
- Rapidly cures into durable finish for facilities that require maximum protection with minimum downtime.
- Reduces maintenance, cleaning costs and costly repairs. Simply damp mop or machine scrub.
UNIQUE CHEMISTRY:
FloorShield-HP-ESP’s unique reactive Nano Lithium technology forms an insoluble permanent bond with concrete rapidly curing (30-60 minutes) into a micro (2-3 mils or 50-75 micron) protective surface film.
FloorShield-HP-ESP’s abrasion properties means it will not flake or peel after installation. Its advanced nano lithium chemistry will not absorb water or affect alkalinity once cured.
With lower viscosity than conventional treatments, FloorShield-HP-ESP provides superior penetration with capillary channels providing a more consistent and uniform cure.
Once it has penetrated into porous concrete surfaces, FloorShield-HP-ESP undergoes a series of chemical reactions resulting in total cross linking, reinforcing and sealing the concrete surface by forming a durable chemical bond with the surface and therefore provides a long-term protection many times longer than conventional concrete sealers.
FloorShield-HP-ESP microfilm- forming treatment offers great stain and abrasion resistance plus great strength and durability than traditional coating, sealers and densifiers. FloorShield-HP-ESP is in a class of its own providing long term protection and shielding surfaces from severe and aggressive industrial environments. With good maintenance, treated surfaces maintain sheen even against heavy pedestrian and traffic wear, as a result, floors treated with FloorShield-HP-ESP last longer and cost less to maintain.
ADVANTAGES:
- Permanent and durable surface resists marks, improves traction and helps prevent waterborne containments staining.
- Easy maintenance, easy re-coating. Won’t build up or yellow.
- Resists strong cleaning compounds, alkalis, solvents, oils and many acids.
- Does not support mildew or fungi growth.
- Forms protective shield for colour retention that is glossy and resistant to UV.
- Treated surfaces require no waxing and provide an immediate glossy sheen, can be buffed to restore original sheen.
- Extremely durable stain resistant microfilm forming surface treatment that will not peel or flake and both chemically and mechanically reacts with the substrate.
- Makes concrete easier to clean, creating an environment that is less susceptible to the proliferation of harmful bacteria.
- USDA/FDA approved for incidental food contact.
- Extends the life expectancy and integrity of concrete and masonry.
- Easy one coat application. High coverage 37-74 m2/lt.
- Can be applied using simple methods such as spray, roller or brush.
APPLICATION:
Step 1 – FloorShield-HP-ESP can be applied to existing cured concrete of any age.
Thoroughly clean all surfaces, mechanically remove any surface laitance and fix or patch any surface damage. Remove any membrane forming curing compounds, oils, grease, sealers, dirt, dust, drywall residue and any other contaminants. We recommend cleaning thoroughly with a black scrubbing pad (light abrasion) and a neutral pH detergent.
We do not recommend etching the surface with an acidic solution as it will require neutralizing thoroughly with neutral pH cleaning agent – if not thoroughly neutralized the low pH will cause whiting of the surface.
For best results sand the surface with a 60-100 grit sanding pad or diamond abrasive pad. Remove dust or dirt with a ride or walk by scrubber using water. Squeegee dry. Avoid using cleaners with citrus or butyl compounds.
Step 2 – Important – allow the surface to dry before proceeding.
Step 3 – Mix shake or stir thoroughly before applying.
Apply FloorShield-HP-ESP with microfiber pad or similar. Spread material thinly and evenly so as to completely cover the substrate. Repeat this step to achieve the desired result.
This builds the stain resistant microfilm over the substrate. It is important to allow 30-60 minutes drying time between coats. It is critical to apply thin coats, thick coats will result in uneven cure with the risk of discolouration and whitening. Buffing between coats will improve sheen and speed curing.
STAIN RESISTANCE:
Smooth trowelled concrete treated with FloorShield-HP-ESP was tested for stain resistance from various substances. These compounds were checked at regular intervals up to 24 hours to determine the amount of penetration or staining after cleaning with a non-abrasive, neutral pH cleaner. After cleaning, the stain was evaluated according to the flowing scale with 0 indicating no change in the appearance of the stain and 10 indicating the stain was completely removed.
0 = No change in stain, very visible
5 = Stain lighter but still very visible
10 = Stain completely removed.
| Exposure Time (Hrs) | ||||
| Test Product | 0.5 | 1 | 1.5 | 24 |
| Balsamic Vinegar | 10 | 10 | 8 | 8 |
| Red Wine | 10 | 10 | 9 | 9 |
| Motor Oil | 10 | 10 | 10 | 10 |
| Transmission Fluid | 10 | 10 | 10 | 10 |
| Skydrol | 10 | 10 | 10 | 6 |
CHEMICAL RESISTANCE:
FloorShield-HP-ESP treatment provides enhanced chemical resistance on the following but not limited to (see table 1)
FINAL RESULTS:
Light pedestrian use within 30-60 minutes, vehicle traffic in 2 hours.
Maximum performance may take up to 14 days to develop, depending on temperature and humidity. Do not allow standing water or puddles of water to be left on the surface (immediately wipe up any spills and or water, it is highly recommended not to clean or scrub the surface for a 7 day period to prevent the possibility of whitening or discolouration.
MAINTENANCE:
Routine sweeping, mopping, washing and mechanical scrubbing of floors with water and neutral pH cleaners 9if necessary) is recommended. Water only is sufficient for most environments.
Do not use cleaners that are acidic or that have citrus or Butyl compounds. Although FloorShield-HP-ESP is chemically resistant and helps reduce staining, its application in specific chemical environments and some acidic concentrates, may etch the surface causing a residual stain. If unsure check with TBAPS. Regular maintenance and cleaning will help prolong surface shine. Wipe up any chemical spills as soon as possible.
Prior to painting, stripping or applying resilient tiles wait 6-12 hours after application and conduct an adhesion test.
Always test adhesion and performance for suitability and desired results before application.
PHYSICAL PROPERTIES:
| Specific Gravity | 1.09 |
| Total Solids | 23% |
| Surface Resistance | 106Ω |
| Flash Point | None |
| V.O.C. Content | <50 g/L |
| Active Ingredients | 100% of solids |
| Shelf Life | 6 months in factory sealed container |
| Abrasion resistance | excellent |
| Freeze point | 0 Celsius |
| Depth of surface penetration | 2 – 8mm |
| Appearance | Milky white aqueous solution |
| pH | 11.5 |
Table 1
ACI Standard 302.1R-89 chemical hardeners can be used to increase concrete resistance to chemicals including but not limited to the following:
Aluminium sulphate Lead refining solutions 10% Potassium Dichromate
Ammonium Chloride Lignite oils Potassium persulphate
Barium hydroxide Machine Oils Potassium Sulphate
Beef fat Magnesium chloride Rapeseed oil
Calcium hydroxide Magnesium sulphate Sea water
Calcium nitrate Manganese sulphate Silage
Carbon dioxide Manure Sodium bromide
Carbonic acid Mash fermenting Sodium carbonate
Castor oil Mercuric chloride Sodium chloride
Coal tar oils Mercurous chloride Sodium dichromate
Cottonseed oils Mine water, waste Sodium nitrite
Creosote Mineral oil Sodium sulphate, 10%
Cresol Molasses Sodium sulphite, 10%
Distillers slop Mustard oil Sodium thiosulphate
Ethylene glycol Nickel sulphate Soybean oil
Ferric chloride Oleic acid, 100% Sugar
Ferric sulphate Olive oil Sulphite liquor
Ferrous chloride Paraffin Tallow and tallow oil
Ferrous sulphate Phenol, 25% Tannic acid
Fish oil Phosphoric acid, 85% Tanning liquor, 10%
Fruit juices Pickling brine, 10% Tobacco
Glucose Poppy seed oil Walnut oil
Glycerine Potassium aluminium sulphate Zinc chloride
Hydrogen sulphide Zinc sulphate Iodine Potassium carbonate Zinc Nitrate Lactic acid, 25% Potassium chloride Zinc sulphate
This information contained herein, is to the best of our knowledge and belief, accurate and is to be used as a guide to product selection. However, since the conditions of handling, installation and use are beyond our control, we make no guarantee of results. When in doubt, please test first.
- Use on interior surfaces only
- Protect from freezing
- Agitate before use
- Keep dry at least 24 hours after installation
- Do not allow standing water to dwell on surface for 7 days
- Do not allow traffic until FloorShield-HP-ESP is allowed to completely dry. Generally 30-60 minutes under typical interior conditions.
- FloorShield-HP-ESP will not bridge or fill cracks and will not salvage honeycombed or structurally unsound surfaces.
- If FloorShield-HP to comes into contact with glass, fabric, metal, or painted surfaces, immediately wipe contaminated surfaces with a damp cloth, then wipe dry with a second clean
Every reasonable effort is made to apply exacting standards both in the manufacture of our products and in the information that we issue concerning these products and their use. We warrant our products to be of good quality and will replace or, at our election, refund the purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors beyond our control. Therefore, except for such replacement or refund, TBA Protective Solutions MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, RESPECTING ITS PRODUCTS, and TBA Protective Solutions shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within one (1) year from the date of shipment. No claim will be considered without such written notice or after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any authorized change in the printed recommendations concerning the use of our products must bear the signature of the TBA Protective Solutions Director. This information and all further technical advice are based on TBA Protective Solutions present knowledge and experience. However, TBA Protective Solutions assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third-party intellectual property rights, especially patent rights. In particular, TBA Protective Solutions disclaims all WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. TBA Protective Solutions SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. TBA Protective Solutions reserves the right to make any changes according to technological progress or further developments. It is the customer’s (Authorized Applicator) responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used.
THE DATA SHEET RELATES TO THE MATERIAL AS SUPPLIED. THE INFORMATION CONTAINED HEREIN IS GIVEN IN GOOD FAITH, BUT NO LIABILITY WILL BE ACCEPTED BY THE COMPANY IN RELATION TO THE SAME. THE ACQUISITION OF ADDITIONAL INFORMATION MAY NECESSITATE REVISIONS TO PARTS OR ALL OF THE DATA SHEET, AND SUCH INFORMATION WILL BE SUPPLIED AS IT BECOMES AVAILABLE.
AS THE COMPANY’S PRODUCTS ARE USED FOR A MULTIPLICITY, OF PURPOSES, AND AS THE COMPANY HAS NO CONTROL OVER THE METHOD OF THEIR APPLICATION OR USE, THE COMPANY EXCLUDES ALL CONDITIONS OR WARRANTIES, EXPRESS OR IMPLIED, BY STATUTE OR OTHERWISE, AS TO THEIR PRODUCTS AND/OR THEIR FITNESS FOR ANY PARTICULAR PURPOSE. ANY TECHNICAL CO-OPERATION BETWEEN THE COMPANY AND THE CUSTOMER IS GIVEN FOR THE CUSTOMER’S ASSISTANCE ONLY AND WITHOUT LIABILITY ON THE PART OF THE COMPANY.





